Ground water (water from wells and dugs) for Physical, classical, small and large instrumental for chemical laboratory and toxicological tests, sampling planning, preservation of test samples
Ground water (water from wells and dugs) physical and chemical testing on-site
Ground water (water from producing and observing wells) physical, classical, small and large instrument for chemical laboratory testing
The test/measured characteristic of the type of test, measuring range
The ID of the test/measurement method
Lower measurement limit of Calcium complexometria: 2.8 mg/dm3
Lower measurement limit of Calcium complexometria: 2.8 mg/dm3
Hungarian standards institution (MSZ) 448-3:1985 Chapter 2
Lower measurement limit of Magnesium: 2 mg/dm3
Hungarian standards institution (MSZ) 448-3:1985 Chapter 3
Lower measurement limit of Hydrogen carbonate: 6,1 mg/dm3
Hungarian standards institution (MSZ) 448-11:1986 Section 6.2.
Lower measurement limit of Carbonate: 6,0 mg/dm3
Hungarian standards institution (MSZ) 448-11:1986 Section 6.2.
Lower measurement limit of All hardness complexometria: 4 CaO mg/dm3
Hungarian standards institution (MSZ) 448-21:1986 Chapter 3
Lower measurement limit of Carbonate hardness: 2.8 CaO mg/dm3
Hungarian standards institution (MSZ): 448-21-1986 Chapter 4
Non-carbonate hardness calculation, Lower measurement limit: 2.2 CaO mg/dm3
Hungarian standards institution (MSZ) 448-21:1986 Chapter 5
Hungarian standards institution (MSZ) 448-20-1990 Chapter 4
Lower measurement of nitrite spectrophotometry limit: 0.02 mg/dm3
Hungarian standards institution (MSZ) 1484-13:2009 Chapter 5.2.
Lower measurement limit of Spectrophotometry nitrate: 0.3 mg/dm3
Hungarian standards institution (MSZ) 1484-13:2009 Section 6.2.
Lower measurement limit of Chloried argentometry: 2 mg/dm3
Lower measurement limit of Ortho phosphate: 0.1 mg/dm3
Hungarian standards institution (MSZ) EN ISO 6878:2004 Chapter 4
Lower measurement limit of Sodium FAAS: 2 mg/dm3
Hungarian standards institution (MSZ) 1484-3:2006 Chapter 6
Lower measurement limit of potassium: 0.1 mg/dm3
Hungarian standards institution (MSZ) 1484-3:2006 Chapter 6
Lower measurement limit of iron FAAS: 20 µg/dm3
Hungarian standards institution (MSZ) 1484-3:2006 Chapter 6
Lower measurement limit of manganese FAAS: 10 µg/dm3
Hungarian standards institution (MSZ) 1484-3:2006 Chapter 6
Lower measurement limit of Aluminum ETA-AAS: 4 µg/dm3
Hungarian standards institution (MSZ) 1484-3:2006 Chapter 7
Lower measurement limit of nickel ETA-AAS: 2 µg/dm3
Hungarian standards institution (MSZ) 1484-3:2006 Chapter 7
Lower measurement limit of lead ETA-AAS: 1 µg/dm3
Hungarian standards institution (MSZ) 1484-3:2006 Chapter 7
Lower measurement limit of Mercury cold vapour AAS: 0.2 µ g/dm3
Hungarian standards institution (MSZ) 1484-3:2006 Chapter 9
Hungarian standards institution (MSZ) 1484-3:2006 Chapter 6
Hungarian standards institution (MSZ) 1484-3:2006 Chapter 6
Lower measurement limit of Chrome ETA-AAS: 5 µg/dm3
Hungarian standards institution (MSZ) 1484-3:2006 Chapter 7
Lower measurement limit of Cobalt FAAS: 1 mg/dm3
Hungarian standards institution (MSZ) 1484-3:2006 Chapter 6
Lower measurement limit of Barium FAAS: 2 mg/dm3
Hungarian standards institution (MSZ) 1484-3:2006 Chapter 6.
Lower measurement limit of Molybdenum ETA-AAS: 4 µ g/dm3
Hungarian standards institution (MSZ) 1484-3:2006 Chapter 6.
Lower measurement limit of Arsenic hidrid AAS lower capacity: 1 µg/dm3
pH value (20 °C), direct potentiometry pH 2-12
Specific electric conductivity (25 °C), lower range capacity of conductimetry: 10 µS/cm
Hungarian standards institution (MSZ) EN 27888:1998
Turbidity Measurement of stray light lower range measurement: 0.25 NTU
Hungarian standards institution (MSZ) EN ISO 7027:2000
Hexane extractable material weighing, lower measurement limit: 10 mg/dm3
Hungarian standards institution (MSZ) 1484:2002
Total and dissolved organic carbon (TOC), lower measurement limit: 5 µ g/dm3
Hungarian standards institution (MSZ) EN 1484:1998
II. On-site inspections of the accredited area
pH value (20 °C), direct potentiometry pH 2-12
Hungarian standards institution (MSZ) 1484-22:2009
Specific electric conductivity (25 °C), lower range capacity of conductimetry: 10 µS/cm
Hungarian standards institution (MSZ) EN 27888:1998
Turbidity Measurement of stray light lower range measurement: 0.25 NTU
Hungarian standards institution (MSZ) EN ISO 7027:2000
Temperature for Water: 1-60 °C for air: 1-60 °C
Hungarian standards institution (MSZ) 448-2:1967 Chapter 1 (withdrawn standard)
Dissolved oxygen, optical probe lower measurement range: 0.05 mg/dm3
Color water testing
Hungarian standards institution (MSZ) EN ISO 7887:2012
Smell organoleptic examination
Hungarian standards institution (MSZ) EN 1622:2007
Lower mesaurement range of ammonium nitrogen Colorimetry: 0.02 mg/dm3
Hungarian standards institution (MSZ) EN ISO 5667-1:2007
Hungarian standards institution (MSZ) EN ISO 5667-1:2013
Hungarian standards institution (MSZ) 22902-1:1989 Chapter 3.
Hungarian standards institution (MSZ) 21464:1988 (withdrawn standard)